{"id":39474,"date":"2021-07-27T13:17:09","date_gmt":"2021-07-27T11:17:09","guid":{"rendered":"https:\/\/www.reersafety.cn\/?page_id=39474"},"modified":"2024-07-16T15:43:50","modified_gmt":"2024-07-16T13:43:50","slug":"en-iso-14119safety-of-machinery","status":"publish","type":"page","link":"https:\/\/www.reersafety.cn\/en\/academy\/industrial-safety-guide\/en-iso-14119safety-of-machinery\/","title":{"rendered":"EN ISO 14119\tSafety of machinery"},"content":{"rendered":"\n<div class=\"row\"  id=\"row-1449269767\">\n\n\n\t<div id=\"col-16214550\" class=\"col small-12 large-12\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n  <div id=\"page-header-701239997\" class=\"page-header-wrapper\">\n  <div class=\"page-title light simple-title\">\n\n    \n    <div class=\"page-title-inner container align-center flex-row medium-flex-wrap row-reverse\" >\n            <div class=\"title-content flex-col flex-left text-left medium-text-center\">\n        <div class=\"title-breadcrumbs pb-half pt-half\"><nav class=\"woocommerce-breadcrumb breadcrumbs uppercase\">Home<\/nav><\/div>      <\/div>\n    <\/div>\n\n       <\/div>\n    <\/div>\n  \n\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n<\/div>\n<div class=\"row\"  id=\"row-2037293584\">\n\n\n\t<div id=\"col-1784345350\" class=\"col small-12 large-12\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<div class=\"row\"  id=\"row-448445113\">\n\n\n\t<div id=\"col-2085202567\" class=\"col small-12 large-12\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div id=\"text-914959560\" class=\"text txt-page-title\">\n\t\t\n\n<h1>EN ISO 14119 Safety of machinery<\/h1>\n\t\t\t<\/div>\n\t\n<h2>Interlocking devices associated with guards &#8211; Principles for design and selection<\/h2>\n\t<div id=\"text-790780958\" class=\"text cutom-ul\">\n\t\t\n\n<h3>New subdivision of the interlocking devices<\/h3>\n<p>Interlocking device interlock (ISO 14119:2013, \u00a7 3.1) &#8211; Mechanical, electrical or other type of device, the purpose of which is to prevent the operation of hazardous machine functions under specified conditions (generally as long as a guard is not closed).<\/p>\n\t\t\n<style>\n#text-790780958 {\n  color: rgb(0,0,0);\n}\n#text-790780958 > * {\n  color: rgb(0,0,0);\n}\n<\/style>\n\t<\/div>\n\t\n<div class=\"row\"  id=\"row-417850973\">\n\n\n\t<div id=\"col-1884014396\" class=\"col medium-4 small-12 large-4\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div id=\"text-3025943682\" class=\"text cutom-ul\">\n\t\t\n\n<h4>Type 1 devices &#8211; Uncoded<\/h4>\n<p>These can be:<\/p>\n<ul>\n<li>Rotary cam<\/li>\n<li>Linear cam<\/li>\n<li>Hinge<\/li>\n<\/ul>\n\t\t\t<\/div>\n\t\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1716982044\" class=\"col medium-6 small-12 large-6\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1829938467\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner image-zoom dark\" >\n\t\t\t<img width=\"566\" height=\"262\" src=\"https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/Rotary_cam.png\" class=\"attachment-large size-large\" alt=\"\" decoding=\"async\" loading=\"lazy\" srcset=\"https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/Rotary_cam.png 566w, https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/Rotary_cam-300x139.png 300w, https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/Rotary_cam-510x236.png 510w\" sizes=\"(max-width: 566px) 100vw, 566px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1829938467 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1060026476\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner image-zoom dark\" >\n\t\t\t<img width=\"566\" height=\"262\" src=\"https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/Linear_cam.png\" class=\"attachment-large size-large\" alt=\"\" decoding=\"async\" loading=\"lazy\" srcset=\"https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/Linear_cam.png 566w, https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/Linear_cam-300x139.png 300w, https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/Linear_cam-510x236.png 510w\" sizes=\"(max-width: 566px) 100vw, 566px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1060026476 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1053673621\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner image-zoom dark\" >\n\t\t\t<img width=\"566\" height=\"262\" src=\"https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/Hinge_cam.png\" class=\"attachment-large size-large\" alt=\"\" decoding=\"async\" loading=\"lazy\" srcset=\"https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/Hinge_cam.png 566w, https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/Hinge_cam-300x139.png 300w, https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/Hinge_cam-510x236.png 510w\" sizes=\"(max-width: 566px) 100vw, 566px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1053673621 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-107894126\" class=\"col medium-2 small-12 large-2\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<p>A: Movable guard<br>B: Actuator (cam)<br>C: Position switch<br>1: Opening direction<\/p>\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n<\/div>\n<div class=\"row\"  id=\"row-1836384213\">\n\n\n\t<div id=\"col-874333485\" class=\"col medium-4 small-12 large-4\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div id=\"text-1017631422\" class=\"text cutom-ul\">\n\t\t\n\n<h4 style=\"text-align: left;\">Type 2 &#8211; Coded<\/h4>\n<p style=\"text-align: left;\">Coded actuator (ISO 14119:2013, \u00a7 3.13). Actuator which is specially designed (e.g. by shape) to actuate a certain position switch.<\/p>\n<ul>\n<li style=\"text-align: left;\">Low level coded actuator: coded actuator for which 1 to 9 variations in code are available.<\/li>\n<li style=\"text-align: left;\">Medium level coded actuator: coded actuator for which 10 to 1000 variations in code are available.<\/li>\n<li style=\"text-align: left;\">High level coded actuator: coded actuator for which more than 1000 variations are available.<\/li>\n<\/ul>\n\t\t\t<\/div>\n\t\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-288903878\" class=\"col medium-6 small-12 large-6\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_878519933\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner image-zoom dark\" >\n\t\t\t<img width=\"566\" height=\"262\" src=\"https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/Positiopn-switch.png\" class=\"attachment-large size-large\" alt=\"\" decoding=\"async\" loading=\"lazy\" srcset=\"https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/Positiopn-switch.png 566w, https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/Positiopn-switch-300x139.png 300w, https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/Positiopn-switch-510x236.png 510w\" sizes=\"(max-width: 566px) 100vw, 566px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_878519933 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-96450226\" class=\"col medium-2 small-12 large-2\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<p>1: Position switch<br>2: Actuator (shaped tongue)<\/p>\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n<\/div>\n<div class=\"row\"  id=\"row-616808434\">\n\n\n\t<div id=\"col-297756517\" class=\"col medium-4 small-12 large-4\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div id=\"text-1284906903\" class=\"text cutom-ul\">\n\t\t\n\n<h4>Type 3 &#8211; Unccoded<\/h4>\n<p>These can be:<\/p>\n<ul>\n<li>Inductive &#8211; Actuated by metal of the guard<\/li>\n<li>Magnetic &#8211; Actuated by uncoded magnet<\/li>\n<li>Capacitive &#8211; Ultrasonic or optical<\/li>\n<\/ul>\n\t\t\t<\/div>\n\t\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-343758160\" class=\"col medium-6 small-12 large-6\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1854150939\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img width=\"566\" height=\"262\" src=\"https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/interloking_proxy-1.png\" class=\"attachment-large size-large\" alt=\"\" decoding=\"async\" loading=\"lazy\" srcset=\"https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/interloking_proxy-1.png 566w, https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/interloking_proxy-1-300x139.png 300w, https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/interloking_proxy-1-510x236.png 510w\" sizes=\"(max-width: 566px) 100vw, 566px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1854150939 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1692929146\" class=\"col medium-2 small-12 large-2\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<p>1: Movable guard<br>2: Interlocking device<br>3: Actuator (inductive, magnetic or capacitive)<br>4: Proximity switch<br>5: Actuating system<br>6: Output system<\/p>\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n<\/div>\n<div class=\"row\"  id=\"row-834051566\">\n\n\n\t<div id=\"col-1632603769\" class=\"col medium-4 small-12 large-4\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div id=\"text-1571795382\" class=\"text custom-ul\">\n\t\t\n\n<h4>Type 4 &#8211; Coded<\/h4>\n<p>These can be:<\/p>\n<ul>\n<li>Magnetic &#8211; Actuated by coded magnet<\/li>\n<li>RFID<\/li>\n<li>Optical &#8211; Actuated by coded optics<\/li>\n<\/ul>\n\t\t\t<\/div>\n\t\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-955445706\" class=\"col medium-6 small-12 large-6\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_232041156\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img width=\"566\" height=\"262\" src=\"https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/Code_position_switch.png\" class=\"attachment-large size-large\" alt=\"\" decoding=\"async\" loading=\"lazy\" srcset=\"https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/Code_position_switch.png 566w, https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/Code_position_switch-300x139.png 300w, https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/Code_position_switch-510x236.png 510w\" sizes=\"(max-width: 566px) 100vw, 566px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_232041156 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-818708675\" class=\"col medium-2 small-12 large-2\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<p>1: Opening direction<br>2: Type 4 interlocking device<br>3: coded RFID tag actuator<br>4: Movable guard<\/p>\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n<\/div>\n<div class=\"row\"  id=\"row-1879025421\">\n\n\n\t<div id=\"col-845051720\" class=\"col medium-4 small-12 large-4\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<h4>Type 5 &#8211; Coded<\/h4>\n<p>These can be: position switch with trapped key interlocking<\/p>\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1052083573\" class=\"col medium-6 small-12 large-6\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1880434305\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img width=\"566\" height=\"155\" src=\"https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/trapped_key.png\" class=\"attachment-large size-large\" alt=\"\" decoding=\"async\" loading=\"lazy\" srcset=\"https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/trapped_key.png 566w, https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/trapped_key-300x82.png 300w, https:\/\/www.reersafety.cn\/wp-content\/uploads\/2021\/07\/trapped_key-510x140.png 510w\" sizes=\"(max-width: 566px) 100vw, 566px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1880434305 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-171300825\" class=\"col medium-2 small-12 large-2\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<p>1: Switch<br>2: Bolt lock<\/p>\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n<\/div>\n\t<div id=\"text-277766856\" class=\"text cutom-ul\">\n\t\t\n\n<h3>Overall system stopping performance and access time (The gards distance)<\/h3>\n<p>The access time shall be calculated by using the distance between the hazard zone and the guard together with the approcach speed (see ISO 13855:2010 for typical values).<\/p>\n<h4>Logical series connection of interlocking devices<\/h4>\n<p>Logical series connection of interlocking device means for NC contacts wired in series or for NO contacts wired in parallel.<\/p>\n<p>Up to now, for a logical series of NC contacts, it is considered a DC = 60%, allowing you to get a PL d (not a PL e). The masking of faults, could lead to a lower diagnostic coverage, so nothing.<\/p>\n<p>Based on DC = \u03bbdd \/ \u03bbd (ratio of detected dangerous failures and total) can easily lead to a DC &lt;60%.<\/p>\n<h4>Interlocking devices based on \u201cfault exclusion\u201d<\/h4>\n<p>The standard specifies that the maximum safety level reached by interlocking devices based on \u201cfault exclusion\u201d is generally PLd. In fact there is the possibility that a single mechanical failure resulting in the loss of the safety function.<\/p>\n<p>For example a mechanical failure relating to the key (actuator), or some part of the mechanical device, can generate false information on the electrical contact output.<\/p>\n<p>In some cases it is still possible reach the safety level PLe. These are cases of \u201cfault exclusion for the guard locking\u201d.<\/p>\n<p>The safety level reached in these cases is not necessarily limited by the faults exclusion of the mechanical locking device.<\/p>\n<p>However, specific requirements must be verified: the holding force specified (FZH) of the protection guard locking device must be sufficient to withstand static forces planned on locking bolt, it is also necessary to prevent any effect on the protection locking device determined by the forces dynamic due to movement of the protection guard.<\/p>\n<h4>Guard lock and Guard interlock<\/h4>\n<p>The standard emphasizes the fact that the interlock function and the lock function are two separate safety functions with PLR that can also be different (PLr Locking &lt;PLr interlock).<\/p>\n<h4>Measures to prevent the defeat of the interlock device<\/h4>\n<p>Guards and protection devices of the machines should not be easy to by-pass or render non-operational (Directive 2006\/42\/EC \u00a71.4.1). Measures required to minimize tampering.<\/p>\n<h4>Defeat (ISO 14119:2013, \u00a7 3.7 and \u00a7 3.8)<\/h4>\n<p>Defeat: action that makes interlocking devices inoperative or bypasses them with the result that a machine is used in a manner not intended by the designer or without the necessary safety measures.<\/p>\n<p>Defeat in a reasonably foreseeable manner: defeat of an interlocking device either manually or by using readily available objects. Measures to reduce the defeat of interlocking devices may be adopted:<\/p>\n<p>Prevent access to the elements which constitute the interlock device: <\/p>\n<ul>\n<li>Mouting out of reach, physical obstruction \/ shielding, Mounting in hidden position)<\/li>\n<li>Preventing substitution of the actuators using encoded interlocking devices<\/li>\n<li>Prevent disassembly or moving of the interlocking devices (welding, gluing, riveting, etc ..)<\/li>\n<li>Status monitoring or cyclic testing of the intelocking device<\/li>\n<li>Adding an additional interlock device with a different principle of implementation. In this case, you will testing diving the plausibility of the state of both devices<\/li>\n<\/ul>\n<p>The table 3 of the standard ISO 14119:2013 specify the additional measures against defeating interlocking devices depending on type.<\/p>\n<h4>The anti-tampering measures in case of magnetic sensors low level encoding (MAGNUS)<\/h4>\n<h4>Mandatory:<\/h4>\n<ul>\n<li>Mouting out of reach places, or mounting recesses and not visible in the machine, or status monitoring<\/li>\n<li>Mounting the actuator so that it is difficult to remove<\/li>\n<\/ul>\n<p>Advice:<\/p>\n<ul>\n<li>Second magnetic sensor<\/li>\n<li>Plausibility check of both sensors<\/li>\n<\/ul>\n\t\t\t<\/div>\n\t\n\t<div id=\"text-352104973\" class=\"text cutom-ul\">\n\t\t\n\n\n\t\t\t<\/div>\n\t\n<div class=\"is-divider divider clearfix\" style=\"max-width:100px;\"><\/div>\n\n<div class=\"row\"  id=\"row-466416377\">\n\n\n\t<div id=\"col-1462752627\" class=\"col medium-4 small-12 large-4\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"ux-menu stack stack-col justify-start ux-menu--divider-solid\">\n\t\t\n\n\t<div class=\"ux-menu-link flex menu-item\">\n\t\t<a class=\"ux-menu-link__link flex\" href=\"https:\/\/www.reersafety.cn\/en\/academy\/industrial-safety-guide\/iec-62061-safety-of-machinery\/design-and-development-of-subsystems\/\"  >\n\t\t\t<i class=\"ux-menu-link__icon text-center icon-angle-left\" ><\/i>\t\t\t<span class=\"ux-menu-link__text\">\n\t\t\t\tConclusions\t\t\t<\/span>\n\t\t<\/a>\n\t<\/div>\n\t\n\n\n\t<\/div>\n\t\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-376734137\" class=\"col medium-4 small-12 large-4\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1285982517\" class=\"col medium-4 small-12 large-4\"  >\n\t\t<div class=\"col-inner text-right\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"ux-menu stack stack-col justify-start ux-menu--divider-solid\">\n\t\t\n\n\t<div class=\"ux-menu-link flex menu-item\">\n\t\t<a class=\"ux-menu-link__link flex\" href=\"https:\/\/www.reersafety.cn\/en\/academy\/industrial-safety-guide\/safe-speed-monitoring\/\"  >\n\t\t\t<i class=\"ux-menu-link__icon text-center icon-angle-right\" ><\/i>\t\t\t<span class=\"ux-menu-link__text\">\n\t\t\t\tSafe speed monitoring\t\t\t<\/span>\n\t\t<\/a>\n\t<\/div>\n\t\n\n\n\t<\/div>\n\t\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n<\/div>\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n<\/div>\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n<\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":7,"featured_media":0,"parent":38823,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"om_disable_all_campaigns":false,"inline_featured_image":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_uf_show_specific_survey":0,"_uf_disable_surveys":false},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>EN ISO 14119 Machinery Safety - Useful Info | ReeR<\/title>\n<meta name=\"description\" content=\"Learn more about EN ISO 14119 for machinery safety with our detailed article. Protect your plant and your operators\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.reersafety.cn\/en\/academy\/industrial-safety-guide\/en-iso-14119safety-of-machinery\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"EN ISO 14119 Machinery Safety - Useful Info | ReeR\" \/>\n<meta property=\"og:description\" content=\"Learn more about EN ISO 14119 for machinery safety with our detailed article. Protect your plant and your operators\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.reersafety.cn\/en\/academy\/industrial-safety-guide\/en-iso-14119safety-of-machinery\/\" \/>\n<meta property=\"og:site_name\" content=\"ReeR\" \/>\n<meta property=\"article:modified_time\" content=\"2024-07-16T13:43:50+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.reersafety.cn\/en\/academy\/industrial-safety-guide\/en-iso-14119safety-of-machinery\/\",\"url\":\"https:\/\/www.reersafety.cn\/en\/academy\/industrial-safety-guide\/en-iso-14119safety-of-machinery\/\",\"name\":\"EN ISO 14119 Machinery Safety - Useful Info | ReeR\",\"isPartOf\":{\"@id\":\"https:\/\/www.reersafety.cn\/en\/#website\"},\"datePublished\":\"2021-07-27T11:17:09+00:00\",\"dateModified\":\"2024-07-16T13:43:50+00:00\",\"description\":\"Learn more about EN ISO 14119 for machinery safety with our detailed article. Protect your plant and your operators\",\"breadcrumb\":{\"@id\":\"https:\/\/www.reersafety.cn\/en\/academy\/industrial-safety-guide\/en-iso-14119safety-of-machinery\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.reersafety.cn\/en\/academy\/industrial-safety-guide\/en-iso-14119safety-of-machinery\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.reersafety.cn\/en\/academy\/industrial-safety-guide\/en-iso-14119safety-of-machinery\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.reersafety.cn\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Academy\",\"item\":\"https:\/\/www.reersafety.cn\/en\/academy\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Safety guide\",\"item\":\"https:\/\/www.reersafety.cn\/en\/academy\/industrial-safety-guide\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"EN ISO 14119 Safety of machinery\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.reersafety.cn\/en\/#website\",\"url\":\"https:\/\/www.reersafety.cn\/en\/\",\"name\":\"ReeR\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.reersafety.cn\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"EN ISO 14119 Machinery Safety - Useful Info | ReeR","description":"Learn more about EN ISO 14119 for machinery safety with our detailed article. Protect your plant and your operators","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.reersafety.cn\/en\/academy\/industrial-safety-guide\/en-iso-14119safety-of-machinery\/","og_locale":"en_US","og_type":"article","og_title":"EN ISO 14119 Machinery Safety - Useful Info | ReeR","og_description":"Learn more about EN ISO 14119 for machinery safety with our detailed article. Protect your plant and your operators","og_url":"https:\/\/www.reersafety.cn\/en\/academy\/industrial-safety-guide\/en-iso-14119safety-of-machinery\/","og_site_name":"ReeR","article_modified_time":"2024-07-16T13:43:50+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.reersafety.cn\/en\/academy\/industrial-safety-guide\/en-iso-14119safety-of-machinery\/","url":"https:\/\/www.reersafety.cn\/en\/academy\/industrial-safety-guide\/en-iso-14119safety-of-machinery\/","name":"EN ISO 14119 Machinery Safety - Useful Info | ReeR","isPartOf":{"@id":"https:\/\/www.reersafety.cn\/en\/#website"},"datePublished":"2021-07-27T11:17:09+00:00","dateModified":"2024-07-16T13:43:50+00:00","description":"Learn more about EN ISO 14119 for machinery safety with our detailed article. Protect your plant and your operators","breadcrumb":{"@id":"https:\/\/www.reersafety.cn\/en\/academy\/industrial-safety-guide\/en-iso-14119safety-of-machinery\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.reersafety.cn\/en\/academy\/industrial-safety-guide\/en-iso-14119safety-of-machinery\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.reersafety.cn\/en\/academy\/industrial-safety-guide\/en-iso-14119safety-of-machinery\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.reersafety.cn\/en\/"},{"@type":"ListItem","position":2,"name":"Academy","item":"https:\/\/www.reersafety.cn\/en\/academy\/"},{"@type":"ListItem","position":3,"name":"Safety guide","item":"https:\/\/www.reersafety.cn\/en\/academy\/industrial-safety-guide\/"},{"@type":"ListItem","position":4,"name":"EN ISO 14119 Safety of machinery"}]},{"@type":"WebSite","@id":"https:\/\/www.reersafety.cn\/en\/#website","url":"https:\/\/www.reersafety.cn\/en\/","name":"ReeR","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.reersafety.cn\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.reersafety.cn\/en\/wp-json\/wp\/v2\/pages\/39474"}],"collection":[{"href":"https:\/\/www.reersafety.cn\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.reersafety.cn\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.reersafety.cn\/en\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.reersafety.cn\/en\/wp-json\/wp\/v2\/comments?post=39474"}],"version-history":[{"count":7,"href":"https:\/\/www.reersafety.cn\/en\/wp-json\/wp\/v2\/pages\/39474\/revisions"}],"predecessor-version":[{"id":57015,"href":"https:\/\/www.reersafety.cn\/en\/wp-json\/wp\/v2\/pages\/39474\/revisions\/57015"}],"up":[{"embeddable":true,"href":"https:\/\/www.reersafety.cn\/en\/wp-json\/wp\/v2\/pages\/38823"}],"wp:attachment":[{"href":"https:\/\/www.reersafety.cn\/en\/wp-json\/wp\/v2\/media?parent=39474"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}